| Cooling Incubator ( BOD Incubator) 
BOD test chambers are especially built to pass FDA and ICH compliance standards and have a reputation for reliability, quality and performance.
- Construction as per cGMP regulations.
- Consisting of refrigeration, air handling, humidification, dehumidification, temperature/humidity controlling
- Microprocessor based PID Temperature controller OR
PLC based system for chamber control and auto changeover of standby system
with touch screen display.
- Printer interface & PC interface for data storage
- Standard networking via Ethernet.
Data Acquisition system complying to US FDA 21 CFR Part 11
- Data records & process control systems have Electronic Signature & Electronic Record capability. The controllers have a lockout feature that permits changes through a 21CFR Part11 compliant operator station, thus providing the necessary audit trail.
- Mean Kinetic Temperature value.
- Password security for log in and door operations.
- Operators need to enter user name and password before taking any action.
- Report search option using date and sample name.
- Secure computer generated, time stamped runtime audit trail of batch stop/start, alarm acknowledgements, logins, signature details, configuration changes.
- User actions with signing and authorization.
- Access control according to authority level.
- Export conversion facility to Excel.



Temperature Data Logger :
4 channel or 8 channel , calibrated data logger to print date, time, temperature set and process values for mapping and auto validation. Features like printer and PC interfacing provided.
Standby Systems:
Standby refrigeration and sensor
Mobile Alert :
- Different Alarm indication through Mobile SMS Alert (from single to multi user)
- Process value indication through Mobile SMS Alert(from single to multi user)
Validation :
DQ/ FAT /IQ / OQ / PQ documentation with test and calibration certificate.
Safety features :
- Special software incorporated in the controller to give ‘FAULT’ indication in case of failure of any control system.
- Audio alarm provided to signal variation in temperature.
- Safety digital temperature controller for main controller : In the event of failure of Micro-PID Controller the high accurate safety controller will take over temperature controlling.
- In built over load protector provided for hermetic sealed compressor.
Temperature Range |
: 5 °C to 60°C |
Accuracy |
: ± 0.2°C |
Temperature uniformity |
: ± 1 °C. |
| |
|
Power supply |
: 1 Phase, 230V ± 10% AC, 50 Hz |
Internal & External dimension :
|